G.J. Streekstra MEng PhD publications

foto

Publications MEng PhD G.J. Streekstra

Positions
Other Academic Staff, Assistant Professor
Main activities
Education, Research, Other
Specialisation
Medical Imaging
Focus of research

 

Orthopedic Imaging
In a longstanding cooperation with the depts. of Radiology, Plastic & Reconstructive Surgery and Orthopedics of the AMC we develop and evaluate 4D-imaging equipment for analysis of 3D patterns of movement of the wrist. This technology enables acquisition of novel 4D diagnostic information which facilitates treatment decision making in wrist problems. Current clinical research using 4D imaging is focused on measurement of dynamic joint space thickness as well as the effect of surgical interventions on 3D motion patterns of the wrist joint.
In a second orthopedic application we develop image based surgical planning and per-operative image analysis methods for minimally invasive corrective osteotomy procedures. This application has been developed in cooperation with our European consortium partners in the MEDIATE project. Currently, a multitude of applications emerges based on technology developed in MEDIATE, including planning of knee surgery and designing patient specific implants.
In cooperation with the Internal Medicine and the Radiology departments we recently started a cooperation with the VUMC on the assessment of bone mineral density in obese patients. Dedicated imaging protocols are being developed to increase the accuracy of bone mineral density measurements and differentiation of bone minerals from bone marrow and fat. In view of the alliance between VU medical center and the AMC this research will be centered in the recently founded MOVEMED institute.
 

Cardiovascular Imaging
In close cooperation with the Radiology department and several clinical departments we develop methods for cardiovascular imaging and image analysis. Focus in this research topic is on image analysis for CT-perfusion imaging, Transcatheter Aortic Valve Implantation (STW project: CARISMA) and remote image analysis for trauma (European grant: MEDUSA) .

 

2021

  • Caiti G., Dobbe J. G. G., Strackee S. D., van Doesburg M. H. M., Strijkers G. J., Streekstra G. J. A 3D printed cast for minimally invasive transfer of distal radius osteotomy: a cadaver study International journal of computer assisted radiology and surgery 2021 [PubMed]
  • Kievit Arthur J., Dobbe Johannes G. G., Mallee Wouter H., Blankevoort Leendert, Streekstra Geert J., Schafroth Matthias U. Accuracy of cup placement in total hip arthroplasty by means of a mechanical positioning device: a comprehensive cadaveric 3d analysis of 16 specimens Hip international 2021;31 (1):58-65 [PubMed]
  • Löke Daan R., Helderman Roxan F. C. P. A., Rodermond Hans M., Tanis Pieter J., Streekstra Geert J., Franken Nicolaas A. P., Oei Arlene L., Crezee Johannes, Kok H. Petra Demonstration of treatment planning software for hyperthermic intraperitoneal chemotherapy in a rat model International journal of hyperthermia 2021;38 (1):38-54 [PubMed]

2020

  • Post Anouk L., Cernohorsky Paul, Pedrigi Ryan M., Streekstra Geert J., d'Hooghe Julia N. S., Annema Jouke T., Strackee Simon D., Krams Rob, van Leeuwen Ton G. J. M., de Bruin Daniel M., Faber Dirk J. 3D co-registration algorithm for catheter-based optical coherence tomography OSA Continuum 2020;3 (10):2707-2721
  • van Gemert Martin J. C., Streekstra Geert J., Vandenbussche Frank P. H. A., Nikkels Peter G. J., van den Wijngaard Jeroen P. H. M. Acardius anceps with neck cyst and cleft palate: Three dimensional skeletal computed tomography reconstruction with discussion of the literature Birth defects research 2020;112 (2):137-140 [PubMed]
  • de Roo Marieke G. A., Dobbe Johannes G. G., Peymani Abbas, van der Made Anne D., Strackee Simon D., Streekstra Geert J. Accuracy of manual and automatic placement of an anatomical coordinate system for the full or partial radius in 3D space Scientific reports 2020;10 (1) [PubMed]
  • van Stijn–Bringas Dimitriades D., Planken R. N., Groenink M., Streekstra G. J., Kuijpers T. W., Kuipers I. M. Coronary artery assessment in Kawasaki disease with dual-source CT angiography to uncover vascular pathology European radiology 2020;30 (1):432-441 [PubMed]
  • Donders J. C. E., Prins J., Kloen P., Streekstra G. J., Cole P. A., Kleipool R. P., Dobbe J. G. G. Correction to: Three‑dimensional topography of scapular nutrient foramina (Surgical and Radiologic Anatomy, (2020), 42, 8, (887-892), 10.1007/s00276-020-02441-7) Surgical and radiologic anatomy 2020;42 (8):893 [PubMed]
  • Brinkhorst Michelle, Streekstra Geert, van Rosmalen Joost, Strackee Simon, Hovius Steven Effects of axial load on in vivo scaphoid and lunate kinematics using four-dimensional computed tomography Journal of hand surgery, European volume 2020;45 (9):974-980 [PubMed]
  • Meinders Marjolein, Shoemark Debbie, Dobbe Johannes G. G., Streekstra Geert J., Frayne Jan, Toye Ashley M. Expression and Retention of Thymidine Phosphorylase in Cultured Reticulocytes as a Novel Treatment for MNGIE Molecular therapy. Methods & clinical development 2020;17:822-830 [PubMed]
  • de Roo Marieke G. A. Four-dimensional imaging of scaphoid kinematics 2020. 255p. ISBN 9789464024869. [UvA Dissertations Online] University of Amsterdam. (Supervisor: van der Horst Chantal M. A. M.; Co-supervisors: Strackee Simon D., Streekstra Geert J.)
  • Donders J. C. E., Wellenberg R. H. H., Streekstra G. J., Maas M., Kloen P. Improved diagnostic confidence in evaluating bone non-union using virtual monochromatic dual-energy CT European journal of radiology 2020;132 [PubMed]
  • Wellenberg R. H. H., Donders J. C. E., Guitton T. G., Streekstra G. J., Kloen P., Maas M. Interdisciplinary consensus of virtual monochromatic dual-energy CT images: is there discrepancy in preferred photon energy between surgeons and radiologists for the assessment of non-unions? Clinical radiology 2020;75 (6):448-456 [PubMed]
  • Wellenberg Ruud H. H., Dobbe Johannes G. G., Erkkilä Jukka, Maas Mario, Streekstra Geert J. Marker-less assessment of the geometric error of fused cone-beam computed tomography images of the foot constructed using stitching software Acta radiologica (Stockholm, Sweden 2020 [PubMed]
  • Moura Pedro L., Hawley Bethan R., Dobbe Johannes G. G., Streekstra Geert J., Rab Minke A. E., Bianchi Paola, van Wijk Richard, Toye Ashley M., Satchwell Timothy J. PIEZO1 gain-of-function mutations delay reticulocyte maturation in hereditary xerocytosis Haematologica 2020;105 (6):e268-e271 [PubMed]
  • Brinkhorst Michelle, Foumani Mahyar, van Rosmalen Joost, Selles Ruud, Hovius Steven, Strackee Simon, Streekstra Geert Quantifying in vivo scaphoid, lunate, and capitate kinematics using four-dimensional computed tomography Skeletal radiology 2020 [PubMed]
  • Hakvoort E. T., Wellenberg R. H. H., Streekstra G. J. Quantifying near metal visibility using dual energy computed tomography and iterative metal artifact reduction in a fracture phantom Physica medica 2020;69:9-18 [PubMed]
  • Moura Pedro L., Dobbe Johannes G. G., Streekstra Geert J., Rab Minke A. E., Veldthuis Martijn, Fermo Elisa, van Wijk Richard, van Zwieten Rob, Bianchi Paola, Toye Ashley M., Satchwell Timothy J. Rapid diagnosis of hereditary haemolytic anaemias using automated rheoscopy and supervised machine learning British journal of haematology 2020;190 (4):e250-e255 [PubMed]
  • Donders J. C. E., Prins J., Kloen P., Streekstra G. J., Cole P., Kleipool R. P., Dobbe J. G. G. Three-dimensional topography of scapular nutrient foramina Surgical and radiologic anatomy 2020;42 (8):887-892 [PubMed]

2019

  • de Roo Marieke G. A., Muurling Marijn, Dobbe Johannes G. G., Brinkhorst Michelle E., Streekstra Geert J., Strackee Simon D. A four-dimensional-CT study of in vivo scapholunate rotation axes: possible implications for scapholunate ligament reconstruction Journal of hand surgery, European volume 2019;44 (5):479-487 [PubMed]
  • Caiti G, Dobbe J G G, Bervoets E, Beerens M, Strackee S D, Strijkers G J, Streekstra G J Biomechanical considerations in the design of patient-specific fixation plates for the distal radius Medical & biological engineering & computing 2019;57 (5):1099-1107 [PubMed]
  • Vlastra W., Claessen B. E., Beijk M. A., Sjauw K. D., Streekstra G. J., Wykrzykowska J. J., Vis M. M., Koch K. T., de Winter R. J., Piek J. J., Henriques J. P. S., Delewi R. Cardiology fellows-in-training are exposed to relatively high levels of radiation in the cath lab compared with staff interventional cardiologists—insights from the RECAP trial Netherlands heart journal 2019;27 (6):330-333 [PubMed]
  • de Roo Marieke G. A., Dobbe Johannes G. G., van der Horst Chantal M. A. M., Streekstra Geert J., Strackee Simon D. Carpal kinematic changes after scaphoid nonunion: an in vivo study with four-dimensional CT imaging Journal of hand surgery, European volume 2019;44 (10):1056-1064 [PubMed]
  • Cernohorsky Paul, Strackee Simon D., Streekstra Geert J., van den Wijngaard Jeroen P., Spaan Jos A. E., Siebes Maria, van Leeuwen Ton G., de Bruin Daniel M. Computed Tomography–Mediated Registration of Trapeziometacarpal Articular Cartilage Using Intraarticular Optical Coherence Tomography and Cryomicrotome Imaging: A Cadaver Study Cartilage 2019 [PubMed]
  • Caiti Giuliana, Dobbe Johannes G. G., Strackee Simon D., Strijkers Gustav J., Streekstra Geert J. Computer-Assisted Techniques in Corrective Distal Radius Osteotomy Procedures IEEE reviews in biomedical engineering 2019;13:233-247 [PubMed]
  • Wellenberg Ruud H. H., van Osch Jochen A. C., Boelhouwers Henk J., Edens Mireille A., Streekstra Geert J., Ettema Harmen B., Boomsma Martijn F. CT radiation dose reduction in patients with total hip arthroplasties using model-based iterative reconstruction and orthopaedic metal artefact reduction Skeletal radiology 2019;48 (11):1775-1785 [PubMed]
  • Hernandez-Giron Irene, den Harder Johan Michiel, Streekstra Geert J., Geleijns Jacob, Veldkamp Wouter J. H. Development of a 3D printed anthropomorphic lung phantom for image quality assessment in CT Physica medica 2019;57:47-57 [PubMed]
  • Dobbe Johannes G. G., de Roo Marieke G. A., Visschers Jim C., Strackee Simon D., Streekstra Geert J. Evaluation of a quantitative method for carpal motion analysis using clinical 3D and 4D CT protocols IEEE transactions on medical imaging 2019;38 (4):1048-1057 [PubMed]
  • Dobbe Johannes G. G., Streekstra Geert J., Blankevoort Leendert, Wiegerinck Johannes I., Maas Mario, Zwiers Ruben, van Dijk C. Niek, Plaaß Christian, Rips Leho, Mansur Nacime Salomão Barbachan, Sampathkumar Kandasam, Ovidiu Muntean George, Russo Alessandro, Burg Alon, Kurup Harish, Boszczyk Andrzej, Gerards Rogier M., Barwick Thomas, Jayaprasad P. S., Kim David, Bojanic Ivan, Darabos Nikica, Vulcano Ettore, Paulick Risi Michelethomas, Kumar Mohan, Laval Georges, Vasilakakos Theofanis, Lopez Astegiano Valeria, Daguerre Gaston, Hajduk Grzegorz, Ceccarini Paolo, de Diego Gutiérrez V. ctor, Brown Christopher, Pécsi Örs, Verbeek Diederik, Thilak Jai, Koukoulias Nikolaos, el Hage Samer, Miranda Vitor, Seybold Jeffrey, Millán Angélica, de Arimathéa Brandão José, Lins Carolina, Pahlplatz Thijs M. J., van Bergen Christiaan J. A., Weel Hanneke, Doornberg Job N., Lansdaal Joris R., Opdam Kim T. M., de Leeuw Peter A. J. Exorotated radiographic views have additional diagnostic value in detecting an osseous impediment in patients with posterior ankle impingement Journal of ISAKOS 2019;4 (4):181-187
  • Severn C. E., Eissa A. M., Langford C. R., Parker A., Walker M., Dobbe J. G. G., Streekstra G. J., Cameron N. R., Toye A. M. Ex vivo culture of adult CD34+ stem cells using functional highly porous polymer scaffolds to establish biomimicry of the bone marrow niche Biomaterials 2019;225 [PubMed]
  • Caiti G, Dobbe J G G, Loenen A C Y, Beerens M, Strackee S D, Strijkers G J, Streekstra G J Implementation of a semiautomatic method to design patient-specific instruments for corrective osteotomy of the radius International journal of computer assisted radiology and surgery 2019;14 (5):829-840 [PubMed]
  • Schallig W., van den Noort J. C., Kleipool R. P., Dobbe J. G. G., van der Krogt M. M., Harlaar J., Maas M., Streekstra G. J. Precision of determining bone pose and marker position in the foot and lower leg from computed tomography scans: How low can we go in radiation dose? Medical engineering & physics 2019 [PubMed]
  • Peymani Abbas, Dobbe Johannes G. G., Streekstra Geert J., McCarroll Henry R., Strackee Simon D. Quantitative three-dimensional assessment of Madelung deformity Journal of hand surgery, European volume 2019;44 (10):1041-1048 [PubMed]
  • Moura Pedro L., Iragorri Maria A. Lizarralde, Français Olivier, le Pioufle Bruno, Dobbe Johannes G. G., Streekstra Geert J., el Nemer Wassim, Toye Ashley M., Satchwell Timothy J. Reticulocyte and red blood cell deformation triggers specific phosphorylation events Blood advances 2019;3 (17):2653-2663 [PubMed]
  • Peymani Abbas, Johnson Anna Rose, Dowlatshahi Arriyan S., Dobbe Johannes G. G., Lin Samuel J., Upton Joseph, Streekstra Geert J., Strackee Simon D. Surgical Management of Madelung Deformity: A Systematic Review Hand (New York, N.Y.) 2019;14 (6):725-734 [PubMed]
  • Caiti Giuliana Take it personally: Advances in custom instrumentation for corrective osteotomy of the radius 2019. 172p. ISBN 9789463612975. [UvA Dissertations Online] University of Amsterdam. (Supervisors: Strijkers G. J. , Dobbe I. G. G.; Co-supervisor: Streekstra G. J.)
  • Colman Kerri L., van der Merwe Alie E., Stull Kyra E., Dobbe Johannes G. G., Streekstra Geert J., van Rijn Rick R., Oostra Roelof-Jan, de Boer Hans H. The accuracy of 3D virtual bone models of the pelvis for morphological sex estimation International journal of legal medicine 2019;133 (6):1853-1860 [PubMed]
  • van Trikt C. H., Dobbe J. G. G., Donders J. C. E., Streekstra G. J., Kloen P. The “coracoid tunnel view”: a simulation study for finding the optimal screw trajectory in coracoid base fracture fixation Surgical and radiologic anatomy 2019;41 (11):1337-1343 [PubMed]
  • Vuurberg G., Dahmen J., Dobbe J. G. G., Kleipool R. P., Stufkens S. A. S., Maas M., Kerkhoffs G. M. M. J., van Dijk C. N., Streekstra G. J. The effect of foot rotation on measuring ankle alignment using simulated radiographs: a safe zone for pre-operative planning Clinical radiology 2019;74 (11):897.e1-897.e7 [PubMed]
  • Colman Kerri L., de Boer Hans H., Dobbe Johannes G. G., Liberton Niels P. T. J., Stull Kyra E., van Eijnatten Maureen, Streekstra Geert J., Oostra Roelof-Jan, van Rijn Rick R., van der Merwe Alie E. Virtual forensic anthropology: The accuracy of osteometric analysis of 3D bone models derived from clinical computed tomography (CT) scans Forensic science international 2019;304 [PubMed]

2018

  • de Roo M. G. A., Dobbe J. G. G., Ridderikhof M. L., Goslings J. C., van der Horst C. M. A. M., Beenen L. F. M., Streekstra G. J., Strackee S. D. Analysis of instability patterns in acute scaphoid fractures by 4-dimensional computed tomographic imaging – A prospective cohort pilot study protocol International Journal of Surgery Protocols 2018;9:1-5
  • van Eijnatten Maureen, van Dijk Roelof, Dobbe Johannes, Streekstra Geert, Koivisto Juha, Wolff Jan CT image segmentation methods for bone used in medical additive manufacturing Medical engineering & physics 2018;51:6-16 [PubMed]
  • de Roo Marieke G. A., Streekstra Geert J., Strackee Jan Dynamic Imaging and Kinematics of the Scaphoidin: Geert A. Buijze, Jesse B. Jupiter, editors. Scaphoid Fractures: Evidence-Based Management. Elsevier gezondheidszorg; 2018. p. 41-47, ISBN 9780323485647
  • Hawksworth Joseph, Satchwell Timothy J., Meinders Marjolein, Daniels Deborah E., Regan Fiona, Thornton Nicole M., Wilson Marieangela C., Dobbe Johannes G. G., Streekstra Geert J., Trakarnsanga Kongtana, Heesom Kate J., Anstee David J., Frayne Jan, Toye Ashley M. Enhancement of red blood cell transfusion compatibility using CRISPR-mediated erythroblast gene editing EMBO molecular medicine 2018;10 (6) [PubMed]
  • Wellenberg Ruud H. H., Donders Johanna C. E., Kloen Peter, Beenen Ludo F. M., Kleipool Roeland P., Maas Mario, Streekstra Geert J. Exploring metal artifact reduction using dual-energy CT with pre-metal and post-metal implant cadaver comparison: are implant specific protocols needed? Skeletal radiology 2018;47 (6):839-845 [PubMed]
  • Bus Mieke T. J., Cernohorsky Paul, de Bruin Daniel M., Meijer Sybren L., Streekstra Geert J., Faber Dirk J., Kamphuis Guido M., Zondervan Patricia J., van Herk Marcel, Laguna Pes Maria P., Grundeken Maik J., Brandt Martin J., de Reijke Theo M., de La Rosette Jean J. M. C. H., van Leeuwen Ton G. Ex-vivo study in nephroureterectomy specimens defining the role of 3-D upper urinary tract visualization using optical coherence tomography and endoluminal ultrasound Journal of medical imaging (Bellingham, Wash.) 2018;5 (1):017001 [PubMed]
  • Fahmi Fahmi, Marquering Henk A., Majoie Charles B., van Walderveen Marianne A., Streekstra Geert J., VanBavel Ed Image Based Automated ASPECT Score for Acute Ischemic Stroke Patientsin: Proceedings of 2017 5th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering, ICICI-BME 2017. Institute of Electrical and Electronics Engineers Inc.; 2018. p. 117-121
  • Collet Carlos, Onuma Yoshinobu, Grundeken Maik J., Miyazaki Yosuke, Bittercourt Marcio, Kitslaar Pieter, Motoyama Sadako, Ozaki Yukio, Asano Taku, Wentzel Jolanda J., Streekstra Geert J., Serruys Patrick W., de Winter Robbert J., Planken R. Nils In vitro validation of coronary CT angiography for the evaluation of complex lesions EuroIntervention 2018;13 (15):1823-1830 [PubMed]
  • Wellenberg R. H. H., Hakvoort E. T., Slump C. H., Boomsma M. F., Maas M., Streekstra G. J. Metal artifact reduction techniques in musculoskeletal CT-imaging European journal of radiology 2018;107:60-69 [PubMed]
  • Dobbe Johannes G. G., Strackee Simon D., Streekstra Geert J. Minimizing the translation error in the application of an oblique single-cut rotation osteotomy: Where to cut? IEEE transactions on bio-medical engineering 2018;65 (4):821 - 827 [PubMed]
  • Moura Pedro L., Hawley Bethan R., Mankelow Tosti J., Griffiths Rebecca E., Dobbe Johannes G. G., Streekstra Geert J., Anstee David J., Satchwell Timothy J., Toye Ashley M. Non-muscle myosin ii drives vesicle loss during human reticulocyte maturation Haematologica 2018;103 (12):1997-2007 [PubMed]
  • Dobbe Johannes G. G., Caiti Giuliana, Schreurs Albert W., Strackee Simon D., Beerens Maikel, Streekstra Geert J. Positioning accuracy of a patient-tailored rimmed wedge implant for corrective osteotomy of the distal radius Medical engineering & physics 2018;58:41-46 [PubMed]
  • Caiti G., Dobbe J. G. G., Strijkers G. J., Strackee S. D., Streekstra G. J. Positioning error of custom 3D-printed surgical guides for the radius: influence of fitting location and guide design International journal of computer assisted radiology and surgery 2018;13 (4):507–518 [PubMed]
  • Kievit A. J., Dobbe J. G. G., Streekstra G. J., Blankevoort L., Schafroth M. U. Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis Knee surgery, sports traumatology, arthroscopy 2018;26 (6):1751-1758 [PubMed]
  • Wellenberg Ruud H. H. Reducing metal artefacts and radiation dose in musculoskeletal CT imaging 2018. [UvA Dissertations Online] University of Amsterdam. (Supervisors: Maas M., Slump C. H.; Co-supervisors: Boomsma M. F., Streekstra G. J.)
  • ten Berg P. W. L., Dobbe J. G. G., Brinkhorst M. E., Meermans G., Strackee S. D., Verstreken F., Streekstra G. J. Scaphoid screw fixation perpendicular to the fracture plane: Comparing volar and dorsal approaches Orthopaedics & traumatology, surgery & research 2018;104 (1):109-113 [PubMed]
  • ten Berg Paul W. L., Dobbe Johannes G. G., Streekstra Geert J. Three-dimensional printed anatomical models in scaphoid surgery Journal of hand surgery, European volume 2018;43 (1):101-102 [PubMed]
  • Tümer Nazlı, Kok Aimee C., Vos Frans M., Streekstra Geert J., Askeland Christian, Tuijthof Gabrielle J. M., Zadpoor Amir A. Three-dimensional registration of freehand-tracked ultrasound to CT images of the talocrural joint Sensors (Basel, Switzerland) 2018;18 (7) [PubMed]

2017

  • Wiggers J. K., Snijders R. M., Dobbe J. G. G., Streekstra G. J., den Hartog D., Schep N. W. L. Accuracy in identifying the elbow rotation axis on simulated fluoroscopic images using a new anatomical landmark Strategies in trauma and limb reconstruction 2017;12 (3):133-139 [PubMed]
  • ten Berg Paul W. L. Characterizing scaphoid nonunion deformity using 2-D and 3-D imaging techniques 2017. 135p. ISBN 9789402805123. [UvA Dissertations Online] University of Amsterdam. (Supervisor: van der Horst C. M. A. M.; Co-supervisors: Streekstra G. J., Strackee S. D., Dobbe J. G. G.)
  • ten Berg P. W. L., Dobbe J. G. G., Brinkhorst M. E., Strackee S. D., Streekstra G. J. Comparing radial styloid size between osteoarthritic and healthy wrists: a pathoanatomical three-dimensional study Journal of hand surgery, European volume 2017;42 (1):63-70 [PubMed]
  • Dobbe J. G. G., du Pré K. J., Blankevoort L., Streekstra G. J., Kloen P. Computer-assisted oblique single-cut rotation osteotomy to reduce a multidirectional tibia deformity: case report Strategies in trauma and limb reconstruction 2017;12 (2):115-120 [PubMed]
  • Vlastra Wieneke, Delewi Ronak, Sjauw Krischan D., Beijk Marcel A., Claessen Bimmer E., Streekstra Geert J., Bekker Robbert J., van Hattum Juliette C., Wykrzykowska Joanna J., Vis Marije M., Koch Karel T., de Winter Robbert J., Piek Jan J., Henriques José P. S. Efficacy of the RADPAD Protection Drape in Reducing Operators' Radiation Exposure in the Catheterization Laboratory: A Sham-Controlled Randomized Trial Circulation. Cardiovascular interventions 2017;10 (11) [PubMed]
  • Peymani A., Foumani M., Dobbe J. G. G., Strackee S. D., Streekstra G. J. Four-dimensional rotational radiographic scanning of the wrist in patients after proximal row carpectomy Journal of hand surgery, European volume 2017;42 (8):846-851 [PubMed]
  • Boomsma Martijn F. Heavy reading in heavy metal: Unraveling the mystery of hip tissue in metal on metal total hip arthroplasty: Unraveling the mystery of hip tissue in metal on metal total hip arthroplasty 2017. 210p. [UvA Dissertations Online] University of Amsterdam. (Supervisors: Maas M. , Verheyen C. C. P. M.; Co-supervisor: Streekstra G. J.)
  • ten Berg Paul W. L., Heeg Erik, Strackee Simon D., Streekstra Geert J. Joint Space Narrowing in Patients With Pisotriquetral Osteoarthritis Hand (New York, N.Y.) 2017;12 (5):490-492 [PubMed]
  • Wellenberg R. H. H., Boomsma M. F., van Osch J. A. C., Vlassenbroek A., Milles J., Edens M. A., Streekstra G. J., Slump C. H., Maas M. Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction Skeletal radiology 2017;46 (5):623-632 [PubMed]
  • Wellenberg R. H. H., Boomsma M. F., van Osch J. A. C., Vlassenbroek A., Milles J., Edens M. A., Streekstra G. J., Slump C. H., Maas M. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses European journal of radiology 2017;88:61-70 [PubMed]
  • Giannakopoulos G. F., Saltzherr T. P., Beenen L. F. M., Streekstra G. J., Reitsma J. B., Bloemers F. W., Goslings J. C., Bakker F. C., Fung Kon Jin P. H. P., Ponsen K. J., Luitse J. S. K., Henny C. P., Dijkgraaf M. G. W., Bossuyt P. M. M. Radiological findings and radiation exposure during trauma workup in a cohort of 1124 level 1 trauma patients Langenbeck s archives of surgery / Deutsche Gesellschaft fur Chirurgie 2017;402 (1):159-165 [PubMed]
  • Naziroglu Robiël E., van Ravesteijn Vincent F., van Vliet Lucas J., Streekstra Geert J., Vos Frans M. Simulation of scanner- and patient-specific low-dose CT imaging from existing CT images Physica medica 2017;36:12-23 [PubMed]
  • Colman Kerri L., Dobbe Johannes G. G., Stull Kyra E., Ruijter Jan M., Oostra Roelof-Jan, van Rijn Rick R., van der Merwe Alie E., de Boer Hans H., Streekstra Geert J. The geometrical precision of virtual bone models derived from clinical computed tomography data for forensic anthropology International journal of legal medicine 2017;131 (4):1155-1163 [PubMed]
  • Colman Kerri L., Dobbe Johannes G. G., Stull Kyra E., Ruijter Jan M., Oostra Roelof Jan, van Rijn Rick R., van der Merwe Alie E., de Boer Hans H., Streekstra Geert J. THE PRECISION OF VIRTUAL PELVISES DERIVED FROM CLINICAL CTIMAGES FOR FORENSIC ANTHROPOLOGY: IAFS 2017: 21st Triennial Meeting of the International Association of Forensic Sciences 2017 Forensic science international 2017;277 (Suppl. 1):92-93 [PubMed]

2016

  • van Lier Monique G. J. T. B., Lopriore Enrico, Vandenbussche Frank P. H. A., Streekstra Geert J., Siebes Maria, Nikkels Peter G. J., Oepkes Dick, van Gemert Martin J. C., van den Wijngaard Jeroen P. H. M. Acardiac twinning: High resolution three-dimensional reconstruction of a low resistance case Birth defects research. Part A, Clinical and molecular teratology 2016;106 (3):213-217 [PubMed]
  • Slaar Annelie, Fockens M. Matthijs, van Rijn Rick R., Maas Mario, Goslings J. Carel, Bakx Roel, Streekstra Geert J., Beenen Ludo F. M., Schep Niels W. L. Adherence to the guidelines of paediatric cervical spine clearance in a level I trauma centre: A single centre experience European journal of radiology 2016;85 (1):55-60 [PubMed]
  • ten Berg P. W. L., Dobbe J. G. G., Horbach S. E. R., Gerards R. M., Strackee S. D., Streekstra G. J. Analysis of deformity in scaphoid non-unions using two- and three-dimensional imaging Journal of hand surgery, European volume 2016;41 (7):719-726 [PubMed]
  • Wellenberg Ruud H. H., Boomsma Martijn F., van Osch Jochen A. C., Vlassenbroek Alain, Milles Julien, Edens Mireille A., Streekstra Geert J., Slump Cornelis H., Maas Mario Computed Tomography Imaging of a Hip Prosthesis Using Iterative Model-Based Reconstruction and Orthopaedic Metal Artefact Reduction: A Quantitative Analysis Journal of computer assisted tomography 2016;40 (6):971-978 [PubMed]
  • Barros Renan Sales, Olabarriaga Silvia Delgado, Borst Jordi, van Walderveen Marianne A. A., Posthuma Jorrit S., Streekstra Geert J., van Herk Marcel, Majoie Charles B. L. M., Marquering Henk A. Dynamic CT perfusion image data compression for efficient parallel processing Medical & biological engineering & computing 2016;54 (2-3):463-473 [PubMed]
  • ten Berg Paul W. L., Dobbe Johannes G. G., Meermans Geert, Strackee Simon D., Verstreken Frederik, Streekstra Geert J. Estimating Scaphoid Lengths Using Anatomical Measurements in the Wrist Journal of hand surgery 2016;41A (9):e279-e284 [PubMed]
  • Oosterhoff Peter, Meijborg Veronique M. F., van Dam Peter M., van Dessel Pascal F. H. M., Belterman Charly N. W., Streekstra Geert J., de Bakker Jacques M. T., Coronel Ruben, Oostendorp Thom F. Experimental Validation of Noninvasive Epicardial and Endocardial Activation Imaging Circulation. Arrhythmia and electrophysiology 2016;9 (8):e004104 [PubMed]
  • Sierink Joanne C., Treskes Kaij, Edwards Michael J. R., Beuker Benn J. A., den Hartog Dennis, Hohmann Joachim, Dijkgraaf Marcel G. W., Luitse Jan S. K., Beenen Ludo F. M., Hollmann Markus W., Goslings J. Carel, Saltzherr T. P., Schep N. W. L., Streekstra G. J., van Lieshout E. M. M., Patka P., Klimek M., van Vugt R., Tromp T. J. N., Brink M., Harbers J. S., El Moumni M., Wendt K. W., Bingisser R., Ummenhofer W., Bless N. Immediate total-body CT scanning versus conventional imaging and selective CT scanning in patients with severe trauma (REACT-2): a randomised controlled trial Lancet 2016;388 (10045):673-683 [PubMed]
  • Kleipool Roeland P., Natenstedt Jerry J., Streekstra Geert J., Dobbe Johannes G. G., Gerards Rogier M., Blankevoort Leendert, Tuijthof Gabriëlle J. M. The Mechanical Functionality of the EXO-L Ankle Brace: Assessment With a 3-Dimensional Computed Tomography Stress Test American journal of sports medicine 2016;44 (1):171-176 [PubMed]
  • ten Berg Paul W. L., Dobbe Johannes G. G., van Wolfswinkel Gerhard, Strackee Simon D., Streekstra Geert J. Validation of the contralateral side as reference for selecting radial head implant sizes Surgical and radiologic anatomy 2016;38 (7):801-807 [PubMed]

2015

  • Walenkamp M. M. J., de Muinck Keizer R. J. O., Dobbe J. G. G., Streekstra G. J., Goslings J. C., Kloen P., Strackee S. D., Schep N. W. L. Computer-assisted 3D planned corrective osteotomies in eight malunited radius fractures Strategies in trauma and limb reconstruction 2015;10 (2):109-116 [PubMed]
  • Fahmi Fahmi CT perfusion for acute ischemic stroke: Vendor-specific summary maps, motion correction and application of time invariant CTA 2015. 140p. ISBN 9789462597211. [UvA Dissertations Online] University of Amsterdam. (Supervisors: van Bavel E. T., Majoie C. B. L. M.; Co-supervisors: Streekstra G. J., Marquering H. A.)
  • Foumani Mahyar Dynamic 3-Dimensional kinematics of the wrist joint and radiocarpal articular contact 2015. 181p. ISBN 9789064649431. [UvA Dissertations Online] University of Amsterdam. (Supervisors: van der Horst C. M. A. M., Grimbergen C. A.; Co-supervisors: Strackee S. D., Blankevoort L., Streekstraa G. J.)
  • Foumani Mahyar, Strackee Simon D., Stekelenburg Carlijn M., Blankevoort Leendert, Streekstra Geert J. Dynamic in vivo evaluation of radiocarpal contact after a 4-corner arthrodesis Journal of hand surgery 2015;40A (4):759-766 [PubMed]
  • van Zwieten Rob, van Oirschot Brigitte A., Veldthuis Martijn, Dobbe Johannes G., Streekstra Geert J., van Solinge Wouter W., Schutgens Roger E. G., van Wijk Richard Partial pyruvate kinase deficiency aggravates the phenotypic expression of band 3 deficiency in a family with hereditary spherocytosis American journal of hematology 2015;90 (3):E35-E39 [PubMed]
  • Dobbe J. G. G., Curnier F., Rondeau X., Streekstra G. J. Precision of image-based registration for intraoperative navigation in the presence of metal artifacts: Application to corrective osteotomy surgery Medical engineering & physics 2015;37 (6):524-530 [PubMed]
  • ten Berg Paul W. L., Dobbe Johannes G. G., Strackee Simon D., Streekstra Geert J. Quantifying scaphoid malalignment based upon height-to-length ratios obtained by 3-dimensional computed tomography Journal of hand surgery 2015;40A (1):67-73 [PubMed]
  • ten Berg Paul W. L., Dobbe Johannes G. G., Strackee Simon D., Streekstra Geert J. Three-Dimensional Assessment of Bilateral Symmetry of the Scaphoid: An Anatomic Study BioMed research international 2015;2015:547250 [PubMed]

2014

  • Fahmi Fahmi, Marquering Henk A., Borst Jordi, Streekstra Geert J., Beenen Ludo F. M., Niesten Joris M., Velthuis Birgitta K., Majoie Charles B. L., VanBavel Ed 3D movement correction of CT brain perfusion image data of patients with acute ischemic stroke Neuroradiology 2014;56 (6):445-452 [PubMed]
  • Fahmi Fahmi, Marquering Henk A., Streekstra Geert J., Beenen Ludo F. M., Janssen Natasja N. Y., Majoie Charles B. L., van Bavel Ed Automatic Detection of CT Perfusion Datasets Unsuitable for Analysis due to Head Movement of Acute Ischemic Stroke Patients Journal of healthcare engineering 2014;5 (1):67-78 [PubMed]
  • Fahmi F., Marquering H. A., Streekstra G. J., Beenen L. F.M., Janssen N. Y., Riordan A., de Jong H., Majoie C. B.L., van Bavel E. Automatic selection of CT perfusion datasets unsuitable for CTP analysis due to head movementin: 13th Mediterranean Conference on Medical and Biological Engineering and Computing 2013 - MEDICON 2013. Springer - Verlag; 2014. p. 336-339, ISBN 9783319008455
  • Dobbe J. G. G., Kievit A. J., Schafroth M. U., Blankevoort L., Streekstra G. J. Evaluation of a CT-based technique to measure the transfer accuracy of a virtually planned osteotomy Medical engineering & physics 2014;36 (8):1081-1087 [PubMed]
  • Dobbe J. G. G., Vroemen J. C., Strackee S. D., Streekstra G. J. Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy Strategies in trauma and limb reconstruction 2014;9 (3):179-183 [PubMed]
  • Wiggers J. K., Streekstra G. J., Kloen P., Mader K., Goslings J. C., Schep N. W. L. Surgical accuracy in identifying the elbow rotation axis on fluoroscopic images Journal of hand surgery 2014;39A (6):1141-1145 [PubMed]
  • Fahmi F., Riordan A., Beenen L. F. M., Streekstra G. J., Janssen N. Y., de Jong H. W., Majoie C. B. L., van Bavel E., Marquering H. A. The effect of head movement on CT perfusion summary maps: simulations with CT hybrid phantom data Medical & biological engineering & computing 2014;52 (2):141-147 [PubMed]

2013

  • Vroemen Joy C. 3D Imaging in corrective osteotomy of the distal radius 2013. 183p. ISBN 9789461694126. [UvA Dissertations Online] University of Amsterdam. (Supervisor: van der Horst C. M. A. M.; Co-supervisors: Strackee S. D., Streekstra G. J., Dobbe J. G. G.)
  • Vroemen Joy C., Dobbe Johannes G. G., Sierevelt Inger N., Strackee Simon D., Streekstra Geert J. Accuracy of distal radius positioning using an anatomical plate Orthopedics 2013;36 (4):e457-e462 [PubMed]
  • de Raedt S., Stilling M., van de Giessen M., Streekstra G. J., Vos F. M., Hansen T. B. A three-dimensional analysis of osteoarthritic changes in the thumb carpometacarpal joint Journal of hand surgery, European volume 2013;38 (8):851-859 [PubMed]
  • Dobbe J. G. G., Vroemen J. C., Strackee S. D., Streekstra G. J. Corrective distal radius osteotomy: including bilateral differences in 3-D planning Medical & biological engineering & computing 2013;51 (7):791-797 [PubMed]
  • Fahmi F., Beenen L. F. M., Streekstra G. J., Janssen N. Y., de Jong H. W., Riordan A., Roos Y. B., Majoie C. B., VanBavel E., Marquering H. A. Head movement during CT brain perfusion acquisition of patients with suspected acute ischemic stroke European journal of radiology 2013;82 (12):2334-2341 [PubMed]
  • Foumani M., Strackee S. D., van de Giessen M., Jonges R., Blankevoort L., Streekstra G. J. In-vivo dynamic and static three-dimensional joint space distance maps for assessment of cartilage thickness in the radiocarpal joint Clinical biomechanics (Bristol, Avon) 2013;28 (2):151-156 [PubMed]
  • Dobbe J. G. G., Vroemen J. C., Strackee S. D., Streekstra G. J. Patient-tailored plate for bone fixation and accurate 3D positioning in corrective osteotomy Medical & biological engineering & computing 2013;51 (1-2):19-27 [PubMed]
  • Vroemen Joy C., Dobbe Johannes G. G., Strackee Simon D., Streekstra Geert J. Positioning evaluation of corrective osteotomy for the malunited radius: 3-D CT versus 2-D radiographs Orthopedics 2013;36 (2):e193-e199 [PubMed]
  • Sierink J. C., Saltzherr T. P., Wirtz M. R., Streekstra G. J., Beenen L. F. M., Goslings J. C. Radiation exposure before and after the introductionof a dedicated total-body CT protocolin multitrauma patients Emergency radiology 2013;20 (6):507-512 [PubMed]
  • Tuijthof G. J. M., Kok A. C., Terra M. P., Aaftink J. F. A., Streekstra G. J., van Dijk C. N., Kerkhoffs G. M. M. J. Sensitivity and specificity of ultrasound in detecting (osteo)chondral defects: a cadaveric study Ultrasound in medicine & biology 2013;39 (8):1368-1375 [PubMed]
  • Boellaard T. N., Henneman O. D. F., Streekstra G. J., Venema H. W., Nio C. Y., van Dorth-Rombouts M. C., Stoker J. The feasibility of colorectal cancer detection using dual-energy computed tomography with iodine mapping Clinical radiology 2013;68 (8):799-806 [PubMed]

2012

  • van de Giessen Martijn, Foumani Mahyar, Vos Frans M., Strackee Simon D., Maas Mario, van Vliet Lucas J., Grimbergen Cornelis A., Streekstra Geert J. A 4D Statistical Model of Wrist Bone Motion Patterns IEEE transactions on medical imaging 2012;31 (3):613-625 [PubMed]
  • van de Giessen Martijn, Vos Frans M., Grimbergen Cornelis A., van Vliet Lucas J., Streekstra Geert J. An efficient and robust algorithm for parallel groupwise registration of bone surfaces Medical image computing and computer-assisted intervention 2012;15 (Part 3):164-171 [PubMed]
  • Walenkamp M. M. J., Dobbe J. G. G., Streekstra G. J., Strackee S. D., Schep N. W. L. Correctie van malunion van de radius met behulp van 3D modellen. Nederlands tijdschrift voor handtherapie 2012;11:8-11
  • Fahmi F., Marquering H. A., Streekstra G. J., Beenen L. F. M., Velthuis B. K., VanBavel E., Majoie C. B. Differences in CT Perfusion Summary Maps for Patients with Acute Ischemic Stroke Generated by 2 Software Packages AJNR. American journal of neuroradiology 2012;33 (11):2074-2080 [PubMed]
  • Boellaard Thierry N., Venema Henk W., Streekstra Geert J., Stoker Jaap Effective Radiation Dose in CT Colonography: Is There a Downward Trend? Academic radiology 2012;19 (9):1127-1133 [PubMed]
  • van de Giessen Martijn, Vos Frans M., Grimbergen Cornelis A., van Vliet Lucas J., Streekstra Geert J. Groupwise rigid registration of wrist bones Medical image computing and computer-assisted intervention 2012;15 (Part 2):155-162 [PubMed]
  • Kalkman J., Bykov A. V., Streekstra G. J., van Leeuwen T. G. Multiple scattering effects in Doppler optical coherence tomography of flowing blood Physics in medicine and biology 2012;57 (7):1907-1917 [PubMed]
  • Vroemen J. C., Dobbe J. G. G., Jonges R., Strackee S. D., Streekstra G. J. Three-Dimensional Assessment of Bilateral Symmetry of the Radius and Ulna for Planning Corrective Surgeries Journal of hand surgery 2012;37A (5):982-988 [PubMed]

2011

  • de Boo D. W., Weber M., Deurloo E. E., Streekstra G. J., Freling N. J., Dongelmans D. A., Schaefer-Prokop C. M. Computed radiography versus mobile direct radiography for bedside chest radiographs: impact of dose on image quality and reader agreement Clinical radiology 2011;66 (9):826-832 [PubMed]
  • Dobbe J. G. G., Pré K. J. du, Kloen P., Blankevoort L., Streekstra G. J. Computer-assisted and patient-specific 3-D planning and evaluation of a single-cut rotational osteotomy for complex long-bone deformities Medical & biological engineering & computing 2011;49 (12):1363-1370 [PubMed]
  • Dobbe J. G. G., Strackee S. D., Schreurs A. W., Jonges R., Carelsen B., Vroemen J. C., Grimbergen C. A., Streekstra G. J. Computer-assisted planning and navigation for corrective distal radius osteotomy, based on pre- and intraoperative imaging IEEE transactions on bio-medical engineering 2011;58 (1):182-190 [PubMed]
  • Carelsen Bart, van Loon Jan, Streekstra Geert J., Maas Mario, van Kemenade Patricia, Strackee Simon D. First experiences with the use of intraoperative 3D-RX for wrist surgery Minimally invasive therapy & allied technologies : MITAT 2011;20 (3):160-166 [PubMed]
  • van de Giessen Martijn, de Raedt Sepp, Stilling Maiken, Hansen Torben B., Maas Mario, Streekstra Geert J., van Vliet Lucas J., Vos Frans M. Localized component analysis for arthritis detection in the trapeziometacarpal joint Medical image computing and computer-assisted intervention 2011;14 (2):360-367 [PubMed]
  • Marquering Henk A., van Ooij Pim, Streekstra Geert J., Schneiders Joppe J., Majoie Charles B., VanBavel Ed, Nederveen Aart J. Multiscale flow patterns within an intracranial aneurysm phantom IEEE transactions on bio-medical engineering 2011;58 (12):3447-3450 [PubMed]
  • Saeed P., van Furth W. R., Tanck M., Kooremans F., Freling N., Streekstra G. J., Regensburg N. I., Berkelbach van der Sprenkel J. W., Peerdeman S. M., van Overbeeke J. J., Mourits M. P. Natural history of spheno-orbital meningiomas Acta neurochirurgica 2011;153 (2):395-402 [PubMed]
  • Buijze Geert A., Dvinskikh Natallia A., Strackee Simon D., Streekstra Geert J., Blankevoort Leendert Osseous and ligamentous scaphoid anatomy: Part II. Evaluation of ligament morphology using three-dimensional anatomical imaging Journal of hand surgery 2011;36A (12):1936-1943 [PubMed]
  • van de Giessen M. Statistical Modeling of shape and motion of the wrist bonesDelft: F&N Boekservice Amsterdam; 2011. 116p. ISBN 9789491098246. [UvA Dissertations Online] TU Delft: Electrical Engineering. (Supervisors: van Vliet L. J., Grimbergen C. A.; Co-supervisors: Vos F., Streekstra G. J.)
  • Dvinskikh N. A., Blankevoort L., Strackee S. D., Grimbergen C. A., Streekstra G. J. The effect of lunate position on range of motion after a four-corner arthrodesis: a biomechanical simulation study Journal of biomechanics 2011;44 (7):1387-1392 [PubMed]

2010

  • Filatov Maxim V., Kaandorp Jaap A., Postma Marten, van Liere Robert, Kruszynski Kris J., Vermeij Mark J. A., Streekstra Geert J., Bak Rolf P. M. A comparison between coral colonies of the genus Madracis and simulated forms Proceedings. Biological sciences / The Royal Society 2010;277 (1700):3555-3561 [PubMed]
  • Gratama van Andel Hugo A. F. Image processing in vascular computed tomography 2010. 203p. [UvA Dissertations Online] University of Amsterdam. (Supervisors: Grimbergen C. A., den Heeten G. J.; Co-supervisors: Venema H. W., Streekstra G. J.)
  • Lagerveld Brunolf W., van Horssen Pepijn, Pes M. Pilar Laguna, van den Wijngaard Jeroen P. H. M., Streekstra Geert J., de La Rosette Jean J. M. C. H., Wijkstra Hessel, Spaan Jos A. E. Immediate Effect of Kidney Cryoablation on Renal Arterial Structure in a Porcine Model Studied by Imaging Cryomicrotome Journal of urology 2010;183 (3):1221-1226 [PubMed]
  • Gratama van Andel H. A. F., Venema H. W., Bol K., Marquering H. A., Majoie C. B., den Heeten G. J., Grimbergen C. A., Streekstra G. J. Model-based measurements of the diameter of the internal carotid artery in CT angiography images Medical physics 2010;37 (11):5711-5727 [PubMed]
  • Streekstra G. J., Dobbe J. G. G., Hoekstra A. G. Quantification of the fraction poorly deformable red blood cells using ektacytometry Optics express 2010;18 (13):14173-14182 [PubMed]
  • Dvinskikh N. A., Blankevoort L., Foumani M., Spaan J. A. E., Streekstra G. J. Quantitative detection of cartilage surfaces and ligament geometry of the wrist using an imaging cryomicrotome system Journal of biomechanics 2010;43 (5):1007-1010 [PubMed]
  • van de Giessen Martijn, Foumani Mahyar, Streekstra Geert J., Strackee Simon D., Maas Mario, van Vliet Lucas J., Grimbergen Kees A., Vos Frans M. Statistical descriptions of scaphoid and lunate bone shapes Journal of biomechanics 2010;43 (8):1463-1469 [PubMed]
  • Foumani M., Blankevoort L., Stekelenburg C., Strackee S. D., Carelsen B., Jonges R., Streekstra G. J. The effect of tendon loading on in-vitro carpal kinematics of the wrist joint Journal of biomechanics 2010;43 (9):1799-1805 [PubMed]

2009

  • van de Giessen Martijn, Streekstra Geert J., Strackee Simon D., Maas Mario, Grimbergen Kees A., van Vliet Lucas J., Vos Frans M. Constrained registration of the wrist joint IEEE transactions on medical imaging 2009;28 (12):1861-1869 [PubMed]
  • Carelsen B., Jonges R., Strackee S., Maas M., van Kemande P., Grimbergen C., van Herk M., Streekstra G. Detection of In Vivo Dynamic 3-D Motion Patterns in the Wrist Joint IEEE transactions on bio-medical engineering 2009;56 (4):1236-1244 [PubMed]
  • Gratama van Andel H. A. F., Venema H. W., Majoie C. B., den Heeten G. J., Grimbergen C. A., Streekstra G. J. Intracranial CT angiography obtained from a cerebral CT perfusion examination Medical physics 2009;36 (4):1074-1085 [PubMed]
  • Foumani M., Strackee S. D., Jonges R., Blankevoort L., Zwinderman A. H., Carelsen B., Streekstra G. J. In-vivo three-dimensional carpal bone kinematics during flexion-extension and radio-ulnar deviation of the wrist: Dynamic motion versus step-wise static wrist positions Journal of biomechanics 2009;42 (16):2664-2671 [PubMed]

2008

  • Marquering Henk A., Stoel Berend C., Dijksta Jouke, Geleijns Koos, Persoon Marion, Wouter Jukema J., Streekstra Geert J., Reiber Johan H.C. CT blurring induced bias of quantitative in-stent restenosis analysesin: Medical Imaging 2008 - Physics of Medical Imaging. 2008., ISBN 9780819470973
  • Rolf Marijn P., ter Wee Rene, van Leeuwen Ton G., Spaan Jos A. E., Streekstra Geert J. Diameter measurement from images of fluorescent cylinders embedded in tissue Medical & biological engineering & computing 2008;46 (6):589-596 [PubMed]
  • Strackee S. D., van Loon J., Foumani M., Maas M., Streekstra G. J., Carelsen B. Intraoperative 3D rotational X-ray in wrist surgery: initial experiences. Medica mundi 2008;52 (3):30-35
  • Carelsen Bart Intraoperative and dynamic 3D rational X-ray imaging 2008. 147p. ISBN 9789090224206. [UvA Dissertations Online] University of Amsterdam. (Supervisor: van Herk M. B.; Co-supervisors: Streekstra G. J., Strackee S. D.)
  • Dobbe J. G. G., Streekstra G. J., Atasever B., van Zijderveld R., Ince C. Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis Medical & biological engineering & computing 2008;46 (7):659-670 [PubMed]

2007

  • Carelsen B., Grolman W., Tange R., Streekstra G. J., van Kemenade P., Jansen R. J., Freling N. J. M., White M. [= Martin], Maat B., Fokkens W. J. Cochlear implant electrode array insertion monitoring with intra-operative 3D rotational X-ray Clinical otolaryngology 2007;32 (1):46-50 [PubMed]
  • van de Giesen M., Vos F. M., Strackee S. D., Maas M., Grimbergen C. A., van Vliet L. J., Streekstra G. J. Constrained registration of multiple rigid objects in close proximity: application in the wrist jointin: A. Anonymous, editors. 4th IEEE International symposium on Biomedical imaging : From nano to macro, ISBI 2007. Piscataway, NJ: IEEE; 2007. p. 704-707, ISBN 9781424406715
  • Streekstra G. J., Strackee S. D., Maas M., ter Wee R., Venema H. W. Model-based cartilage thickness measurement in the submillimeter range Medical physics 2007;34 (9):3562-3570 [PubMed]
  • Gratama van Andel H. A. F., Venema H. W., Streekstra G. J., van Straten M., Majoie C. B. L. M., den Heeten G. J., Grimbergen C. A. Removal of bone in CT angiography by multiscale matched mask bone elimination Medical physics 2007;34 (10):3711-3723 [PubMed]

2006

  • Grolman W., Carelsen B., Tange R. A., Streekstra G. J., van Kemenade P., Fokkens W. J. Cochlea implantatie met per-operatieve 3D röntgen Nederlands tijdschrift voor keel-neus-oorheelkunde 2006;12 (4):222
  • Haverlag R., Ponsen K. J., Luitse J. F. L., van Scherpenzeel K. M., Carelsen B., Streekstra G. J., van Kemenade P., Goslings J. C. Intraoperative 3D-RX imaging of the extremities for trauma surgeryin: Medimond International Proceedings. S.l.: s.n.; 2006. p. 241-244, ISBN 9788875872410
  • Haverlag R., Ponsen K. J., Luitse J. F. L., van Scherpenzeel K. M., Goslings J. C., Carelsen B., Streekstra G. J., van Kemenade P. The use of intraoperative 3D-RX imaging in trauma surgery of the extremities Medica mundi 2006;50 (2):28-32

2005

  • Carelsen Bart, Bakker Niels H., Strackee Simon D., Boon Sjirk N., Maas Mario, Sabczynski Jörg, Grimbergen Cornelis A., Streekstra Geert J. 4D rotational x-ray imaging of wrist joint dynamic motion Medical physics 2005;32 (9):2771-2776 [PubMed]
  • de Bruin P. W., Dercksen V. J., Post F. H., Vossepoel A. M., Streekstra G. J., Vos F. M. Interactive 3D segmentation using connected orthogonal contours Computers in biology and medicine 2005;35 (4):329-346 [PubMed]
  • van Straten M., Venema H. W., Streekstra G. J., Majoie C. B. L. M., den Heeten G. J., Grimbergen C. A. Removal of bone in CT angiography of the cervical arteries by piecewise matched mask bone elimination (vol 31, pg 2924, 2004) Medical physics 2005;32 (1):303
  • Spaan J. A. E., ter Wee R., van Teeffelen J. W. G. E., Streekstra G., Siebes M., Kolyva C., Vink H., Fokkema D. S., VanBavel E. Visualisation of intramural coronary vasculature by an imaging cryomicrotome suggests compartmentalisation of myocardial perfusion areas Medical & biological engineering & computing 2005;43 (4):431-435 [PubMed]

2004

  • van der Leij C. H., Streekstra G. J., Strackee S. D., Maas M. Beeldvorming ten behoeve van het meten van de dikte van kraakbeen in de carpus Nederlands tijdschrift voor geneeskunde 2004;148 (17):863
  • Streekstra G. J., Brascamp P., van der Leij C. H., ter Wee R., Strackee S. D., Maas M., Venema H. W. Cartilage thickness measurement in the sub-millimeter rangein: C. Barillot, D. R. Haynor, P. Hellier, editors. MICCAI 2004, LNCS (Lecture notes in computer science) 3217. Berlin-Heidelberg: Springer-Verlag; 2004. p. 950-958, ISBN 9783540229773
  • van Straten Marcel, Venema Henk W., Streekstra Geert J., Majoie Charles B. L. M., den Heeten Gerard J., Grimbergen Cornelis A. Removal of bone in CT angiography of the cervical arteries by piecewise matched mask bone elimination Medical physics 2004;31 (10):2924-2933 [PubMed]
  • Streekstra G. J., Brascamp P., van der Leij C. H., Strackee S. D., Maas M. Sub-millimeter cartilage thickness measurement from CT imagesin: Proceedings RSNA 2004. S.l.: s.n.; 2004.
  • Dobbe J. G. G., Hardeman M. R., Streekstra G. J., Grimbergen C. A. Validation and application of an automated rheoscope for measuring red blood cell deformability distributions in different species Biorheology 2004;41 (2):65-77 [PubMed]

2003

  • van Straten Marcel, Venema Henk W., Streekstra Geert J., Reekers Jim A., den Heeten Gerard J., Grimbergen Cornelis A. Removal of arterial wall calcifications in CT angiography by local subtraction Medical physics 2003;30 (5):761-770 [PubMed]
  • Dobbe Johannes G. G., Streekstra Geert J., Strackee Jan, Rutten Marcel C. M., Stijnen Johannes M. A., Grimbergen Cornelis A. Syllectometry: The effect of aggregometer geometry in the assessment of red blood cell shape recovery and aggregation IEEE transactions on bio-medical engineering 2003;50 (1):97-106 [PubMed]

2002

  • Streekstra Geert J., van Pelt Jaap Analysis of tubular structures in three-dimensional confocal images Network (Bristol, England) 2002;13 (3):381-395 [PubMed]
  • Dobbe J. G. G., Hardeman M. R., Streekstra G. J., Strackee J., Ince C., Grimbergen C. A. Analyzing red blood cell-deformability distributions Blood cells, molecules & diseases 2002;28 (3):373-384 [PubMed]
  • Dobbe J. G. G. Engineering developments in hemorheology 2002. 133p. [UvA Dissertations Online] University of Amsterdam. (Supervisors: Grimbergen C. A., Ince C.; Co-supervisors: Hardeman M. R., Streekstra G. J.)
  • Dobbe J. G. G., Streekstra G. J., Hardeman M. R., Ince C., Grimbergen C. A. Measurement of the distribution of red blood cell deformability using an automated rheoscope Cytometry 2002;50 (6):313-325 [PubMed]

2001

  • Streekstra G. J., van den Boomgaard R., Smeulders A. W. M. Scale dependency of image derivatives for feature measurement in curvilinear structures INTERNATIONAL JOURNAL OF COMPUTER VISION 2001;42 (3):177-189
  • Bergsma C. B., Streekstra G. J., Smeulders A. W., Manders E. M. Velocity estimation of spots in three-dimensional confocal image sequences of living cells Cytometry 2001;43 (4):261-272 [PubMed]

1995

  • Bronkhorst P. J., Streekstra G. J., Grimbergen J., Nijhof E. J., Sixma J. J., Brakenhoff G. J. A new method to study shape recovery of red blood cells using multiple optical trapping Biophysical journal 1995;69 (5):1666-1673 [PubMed]

1994

  • Streekstra G. J., Hoekstra A. G., Heethaar R. M. Anomalous diffraction by arbitrarily oriented ellipsoids: applications in ektacytometry Applied optics 1994;33 (31):7288-7296 [PubMed]
  • Streekstra G. J., Zwaginga J. J., Nijhof E. J., Sixma J. J., Heethaar R. M. THE RELATION BETWEEN BLOOD-VISCOSITY AND PLASMA VISCOSITY IN THE NEPHROTIC SYNDROME CLINICAL HEMORHEOLOGY 1994;14 (6):769-778

1993

  • Streekstra G. J., Hoekstra A. G., Nijhof E. J., Heethaar R. M. Light scattering by red blood cells in ektacytometry: Fraunhofer versus anomalous diffraction Applied optics 1993;32 (13):2266-2272 [PubMed]

1989

  • SCHASFOORT R. B. M., Streekstra G. J., BERGVELD P., KOOYMAN R. P. H., Greve J. INFLUENCE OF AN IMMUNOLOGICAL PRECIPITATE ON DC AND AC BEHAVIOR OF AN ISFET SENSORS AND ACTUATORS 1989;18 (2):119-129